TM 5-3805-255-14
0018
Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
SERVICE
CAPABLE IF:
ITEM NO. INTERVAL
PROCEDURE
i. Fill reservoir. Refer to "Hydraulic
Hydraulic
32
Reservoir Oil Filling" in this work
Reservoir Filter
(Cont.)
package.
Service
Hydraulic
WARNING
33
Reservoir Oil
Prior to removing reservoir fill cap, operate hydraulic controls
Filling
several times to help relieve hydraulic pressure. Failure to
comply may cause injury to personnel and damage to
equipment.
a. Remove reservoir filler cap and
Class III oil leak is evident.
dipstick.
b. Fill reservoir with clean oil up to "H"
mark on dipstick. Refer to Table 6,
grade and quantity of fluid required.
c. Install and tighten reservoir filler
cap.
d. Start engine and operate boom and
bucket several times to fill hydraulic
cylinders with oil.
e. Lower bucket to ground and shut
WARNING
Always loosen filler cap slowly to relieve pressure build-up in
system. Failure to comply may cause injury to personnel and
damage to equipment.
f. Slowly remove reservoir filler cap
and dipstick and check oil level. Fill
reservoir as necessary to bring level
up to "H" mark on dipstick.
g. Install filler cap and tighten. Check
reservoir for leakage.
0018-50