TM 5-3805-255-14
0018
Table 1. Field PMCS for the H100C Loader - (Continued).
LOCATION
ITEM TO
NOT FULLY MISSION
CHECK/
ITEM NO. INTERVAL
CAPABLE IF:
SERVICE
PROCEDURE
Weekly
Batteries and
a. Disconnect battery cables from
34
a. Battery leaking electrolyte.
Cables
battery.
b. Broken and corroded
b. Check liquid level.
connections or frayed/burned/
melted cables and clamps are
evident.
WARNING
Batteries give off highly flammable gas. Never allow sparks or
open flame near the batteries. Avoid spilling any electrolyte on
skin or clothing. Failure to comply may cause injury to
personnel and damage to equipment.
Before servicing batteries, ensure battery cables are
disconnected from battery. Failure to follow this warning may
result in injury to personnel.
c. Replace worn, cracked, broken, or
corroded cables.
d. Keep batteries fastened securely in
frame.
CAUTION
Do not over tighten battery hold-downs. Excessive tightening
can warp or crack battery case.
e. Maintain correct battery liquid level.
Refer to "Battery Liquid Level" in this
work package.
f. If top of a battery is dirty, it may be Battery leaking electrolyte.
cleaned with a brush. Clean terminal
contact surfaces with steel wool or a
stiff brush.
0018-51