REMOVAL CONTINUED
NOTE
Tag and identify all hoses, lines, and wires for aid in assembly.
2. Remove lamp (Figure 2, Item 4) from gauge (Figure 2, Item 3).
3. Loosen fitting (Figure 2, Item 10) and disconnect line (Figure 2, Item 11) from gauge (Figure 2, Item 3).
4. Remove wire (Figure 2, Item 6) from sending unit (Figure 2, Item 7).
5. Remove sending unit (Figure 2, Item 7) from fitting (Figure 2, Item 9).
6. Remove fitting (Figure 2, Item 9) from gauge (Figure 2, Item 3).
7. Remove two nuts (Figure 2, Items 1 and 5) and bracket (Figure 2, Item 8) from gauge (Figure 2, Item 3).
8. Remove gauge (Figure 2, Item 3) from front of gauge panel (Figure 2, Item 2).