TM 5-3805-262-203-10. INSTRUMENT PANELS TROUBLESHOOTING (CONT)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION10. AIR PRESSURE GAGE DOES NOT OPERATE (Cont).S t e p 1 . ( C o n t ).a. If air pressure gage pointer moves to bottom, refer to page 3-93sending units troubleshooting.b. If air pressure gage pointer2 below.Step 2.Check wiring connection betweensender.a. If wiring connection is bad,sary (page 5-168 or 5-174).does not move to bottom, go to stepair pressure gage and air pressurerepair or replace wiring as neces-b. If wiring is okay, remove instrument cluster (page 5-34) andcheck air pressure gage (page 5-41). If gage is bad, replace(page 5-39). If gage is okay, replace circuit board (page 5-39).11. WATER TEMPERATURE GAGE DOES NOT OPERATE.Step 1.Disconnect blue-yellow wire from terminal of water temperature send-ing unit (page 5-120).Tell an assistant to holdground.Place ignition key switchgage. Gage pointer shouldblue-yellow wire terminal against loaderin on position and watch water temperaturemove to top.a. If water temperature gage pointer moves to top, refer to page3 - 93 sending units troubleshooting.b. If water temperature gage pointer does not move to top, go tostep 2 below.Step 2.Check wiring connection between water temperature gage and watertemperature sending unit.a. If wiring connection is bad, repair or replace wiring as neces-sary (page 5-168 or 5-174).b. If wiring is okay, remove instrument cluster (page 5-34) andcheck water temperature gage (page 5-41). If gage is bad,replace (page 5-39). If gage is okay, replace circuit board(page 5-39).3-80