DISASSEMBLY (SHEET 2 OF 2)
NOTE
Dont clean secondary element assembly.
b e r e p l a c e d e v e r y t h i r d s e r v i c i n g o f
Secondary element assembly shall
primary element assembly, when
s e c o n d a r y e l e m e n t a s s e m b l y i s m o r e t h a n t w o y e a r s o l d ( d a t e
manufacture is stamped on top of secondary element assembly), when it
d a m a g e d , o r w h e n r e d i n d i c a t o r b a n d i n r e s t r i c t i o n i n d i c a t o r s t a ys
view after primary element assembly has been cleaned or replaced.
(g) Remove secondary element assembly (31).
o f
i s
i n
(h) Grasp vacuator valve (32) and pull off air cleaner body (36). Dump any
dust or dirt in vacuator valve.
(i) Loosen two screws (33). Remove two bands (34) from air cleaner.
(j) If necessary, remove pipe cap (35).