TM 5-3805-262-20
4-2. FUEL SYSTEM MAINTENANCE (CONT)
d. A i r C l e a n e r ( c o n t ).
(2) Replacement (cont).
CLEANING (SHEET 1 OF 2)
Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.
W e a r p r o t e c t i v e g o g g l e s a n d g l o v e s a n d u s e o n l y i n a w e l l v e n t i l a t ed
a r e a . A v o i d c o n t a c t w i t h s k i n ,
e y e s a n d c l o t h e s a n d d o n t b r e a t h e
v a p o r s .
Do not use near open flame or excessive heat and dont smoke
w h e n u s i n g i t . F a i l u r e t o d o s o c o u l d c a u s e s e r i o u s i n j u r y . I f y ou
b e c o m e d i z z y w h i l e u s i n g c l e a n i n g s o l v e n t , g e t f r e s h a i r a n d m e d i c al
a t t e n t i o n i m m e d i a t e l y . I f c o n t a c t w i t h s k i n o r c l o t h e s i s m a d e , f l u sh
w i t h l a r g e a m o u n t s o f w a t e r .
If contact with eyes is made, wash eyes
with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 psi. Use
o n l y w i t h e f f e c t i v e c h i p g u a r d i n g a n d p e r s o n a l p r o t e c t i v e e q u i p m e nt
( g o g g l e s / s h i e l d , g l o v e s,
e t c ) . F a i l u r e t o d o s o c o u l d c a u s e s e r i o u s
i n j u r y t o e y e s a n d p o s s i b l e b l i n d n e s s .
If you hurt your eyes or if a
f o r e i g n o b j e c t i s b l o w n i n t o y o u r e y e s , s e e k m e d i c a l a t t e n t i o n
immediately.
(a) Clean all metallic parts using cleaning solvent P-D-680; dry using
compressed air.
(b) Clean tube (13) using detergent; dry using clean cloth.
(c) Wash precleaned bowl (25) in solution of water and detergent. Dry using
c l e a n c l o t h.
NOTE
Dont use compressed air to dry primary element assembly (29). To do so
may cause damage to primary element assembly.
(d) Clean primary element assembly (29) by washing using detergent. Allow
primary element assembly to air dry.
4-26