TM 5-3805-262-20
5-3. STARTER MAINTENANCE (CONT)
b. Circuit Breakers and Relays (cont).
INSTALLATION (SHEET 3 OF 4)
( 7 ) A t t o p o f b r a c k e t ( 3 8 ),
install cab relay (19) using two capscrews (18),
lock washers (17), and nuts (16).
(8) At cab relay (19), connect two wiring harness violet wire terminals (15)
to center terminal stud as tagged.
( 9 ) I n s t a l l n u t ( 1 4 ) a n d t i g h t e n t o 1 6 t o 3 0 l b - i n.
(10) Connect two wiring harness orange-black wire terminals (13) and one end
of wire (6) to large terminal studs as tagged.
(11) Install nuts (11 and 12) and tighten to 35 lb-in.
5-32