TM 5-3805-262-205-3. STARTER MAINTENANCE (CONT)b. Circuit Breakers and Relays (cont).INSTALLATION (SHEET 3 OF 4)( 7 ) A t t o p o f b r a c k e t ( 3 8 ),install cab relay (19) using two capscrews (18),lock washers (17), and nuts (16).(8) At cab relay (19), connect two wiring harness violet wire terminals (15)to center terminal stud as tagged.( 9 ) I n s t a l l n u t ( 1 4 ) a n d t i g h t e n t o 1 6 t o 3 0 l b - i n.(10) Connect two wiring harness orange-black wire terminals (13) and one endof wire (6) to large terminal studs as tagged.(11) Install nuts (11 and 12) and tighten to 35 lb-in.5-32