TM 5-3805-262-20REMOVAL (SHEET 4 OF 4)(13)(14)(15)(16)(17)Loosen and remove nut (25) and tag and disconnect wiring harness terminal(26).Loosen and remove nut (27) and tag and disconnect wire (28) terminal.Loosen and remove two nuts (29),lock washers (30), and capscrews (31).Remove starter relay (33) and pull wiring harness terminals (32) and wire(28) terminal from capscrew (31).If necessary, remove nuts (34), lock washers (35), washers (36) and cap-screws (37) and lower bracket (38) from hood post. Push clamp with reara x l e b r e a t h e r a s i d e .CLEANINGDry cleaning solvent P-D-680 used to clean parts is toxic and flammable.W e a r p r o t e c t i v e g o g g l e s a n d g l o v e s a n d u s e o n l y i n a w e l l v e n t i l a t eda r e a . A v o i d c o n t a c t w i t h s k i n , e y e s a n d c l o t h e s a n d d o n ’ t b r e a t hev a p o r s.Do not use near open flame or excessive heat and don-t smokewhen using it. Failure to do so could cause serious injury. If you be-c o m e d i z z y w h i l e u s i n g c l e a n i n g s o l v e n t , g e t f r e s h a i r a n d m e d i c ala t t e n t i o n i m m e d i a t e l y .If contact with skin or clothes is made, flushwith large amounts of water.I f c o n t a c t w i t h e y e s i s m a d e , w a s h e y eswith water and get medical aid immediately.(1)Wipe exterior of circuit breakers (10) and relays (19 and 33) using cleanc l o th(2)Cleang e n t .(3)Cleanmoistened with cleaning solvent P-D-680. Dry using clean cloths.cable and wire insulation using clean cloth moistened with deter-Dry using clean cloth.wire and cable terminals using clean cloth moistened with isopropyla l c o h o l .(4)Clean all other metallic parts using clean cloth moistened with cleaningsolvent P-D-680. Dry using clean cloths.INSPECTION, TESTING, AND REPAIR (SHEET 1 OF 2)(1)(2)Inspect wires (3, 5, 6, and 28) for cracked or broken insulation or bro-ken wire strands at connection to terminals. Repair cracked or broken in-sulation by applying insulation tape to area. If broken wire strands areseen, replace wire.Inspect starter solenoid cables (21 and 23) for cracked or broken insu-lation or broken wire strands at connection to terminals. Repair crackedor broken insulation by applying insulation tape to area. If broken wirestrands are seen, replace cable (page 5-16).5-29
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business