TM 5-3805-262-205-5. RETURN-TO-DIG AND BUCKET HEIGHT SWITCHES MAINTENANCE (CONT) REMOVAL ( SHEET 3 OF 3)h. At hydraulic control valve, loosen and remove nut (20) and lock washer (21)while an assistant holds capscrew using socket wrench.i. Disconnect ground wire (22) terminal and front wiring harness terminal (23)from capscrew.j. Disconnect ground wire (22) bullet terminal from two wiring harness bulletterminals (24) by grasping with fingers and pulling apart. Then remove groundw i r e ( 2 2 ) .k. Disconnect two wiring harness bullet terminals (25) from brown-white and blue-white wire bullet terminals (26) by grasping with fingers and pulling apart.l. Note routing of wiring harnesses (19 and 27) for installation and remove har-nesses from loader.5-70
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business