TM 5-3805-262-20
5-5. RETURN-TO-DIG AND BUCKET HEIGHT SWITCHES MAINTENANCE (CONT)
INSTALLATION (SHEET 1 OF 3)
a .
b .
c .
d .
e .
f .
Route and position wiring harnesses (19 and 27) as noted during removal.
Connect wiring harness (19) and brown-white wire bullet terminals (25 and 26)
by grasping both in your fingers, alining, then firmly pushing them together.
Connect wiring harness (27) and blue-white wire bullet terminals (25 and 26)
by grasping both in your fingers, alining, then firmly pushing them together.
Connect two wiring harness bullet terminals (24) to ground wire (22) bullet
terminal by grasping with fingers, alining, then firmly pushing them together.
At hydraulic control valve, connect wiring harness terminal (23) and ground
wire (22) terminal to capscrew.
While an assistant holds capscrew with socket wrench, install lock washer (21)
and nut (20). Tighten nut (20) to 65 to 85 lb-ft .
5-72