TM 5-3805-262-205-8. SENDING UNITS AND WARNING SWITCHES MAINTENANCE (CONT)d. Converter Temperature Sending Unit.This task covers removal, cleaning,inspection, testing and repair, and installation of torque converter temperaturesending unit and its associated wiring.TOOLS: No. 1 Common Organizational Maintenance Tool KitCombination box and open end wrench setSocket wrench set, 3/8 inch driveE l e c t r i c a l r e p a i r t o o l k itMultimeterMATERIALS/PARTS: Clean cloths (Appendix C, item 1)Cleaning solvent P-D-680 (Appendix C, item 2)Detergent (Appendix C, item 3)Insulation tape (Appendix C, item 5)Isopropyl alcohol (Appendix C, item 15)Electrical cleaner (Appendix C, item 19)Electrical sealer (Appendix C, item 20)NOTEPRELIMINARY PROCEDURE: Engine right front side panel removed (page9 - 1 4 ) .5-124