TM 5-3805-262-20
6-1. TRANSMISSION MAINTENANCE (CONT)
a. T r a n s m i s s i o n ( c o n t ).
( 2 ) S e r v i c i n g ( c o n t ).
DRAINING AND REFILLING OIL (SHEET 1 OF 3)
( a ) O p e r a t e e n g i n e a t i d l e s p e e d u n t i l t r a n s m i s s i o n o i l r e a c h e s o p e r a t i n g
temperature as indicated by CONV TEMP gage then turn off engine.
(b) Place ten gallon container under transmission drain plug.
(c) Using clean cloth, remove dirt and oil from around drain plug.
(d) Remove drain plug and drain oil into container; discard oil.
( e ) R e i n s t a l l d r a i n p l u g ; t i g h t e n s e c u r e l y.
D r y c l e a n i n g s o l v e n t P - D - 6 8 0 u s e d to
c l e a n p a r t s
i s t o x i c a n d f l a m m a b l e.
Wear protective goggles and gloves and
u s e o n l y i n a w e l l v e n t i l a t e d a r e a .
A v o i d c o n t a c t w i t h s k i n , e y e s a n d
c l o t h e s a n d d o n t b r e a t h e v a p o r s . D o
n o t u s e n e a r o p e n f l a m e o r e x c e s s i ve
h e a t a n d d o n t s m o k e w h e n u s i n g i t .
F a i l u r e t o d o s o c o u l d c a u s e s e r i o u s
injury. If you become dizzy while using
c l e a n i n g s o l v e n t , g e t f r e s h a i r a n d
m e d i c a l a t t e n t i o n i m m e d i a t e l y . I f
c o n t a c t w i t h s k i n o r c l o t h e s i s m a d e ,
f l u s h w i t h l a r g e a m o u n t s o f w a t e r . If
c o n t a c t w i t h e y e s i s m a d e , w a s h e y e s
w i t h w a t e r a n d g e t m e d i c a l a i d
immediately.
(f) Using clean cloth moistened with cleaning solvent, clean area
surrounding suction strainer.
(g) Remove six capscrews (1) and
lock washers (2).
(h) Remove suction strainer (3)
and gasket (4); discard
g a s k e t .
( i ) C l e a n s u c t i o n s t r a i n e r
screen; dry with clean
c l o t h.
6-6