TM 5-3805-262-20INSTALLATION ( SHEET 2( j )(k)( l )(m)(n)If vacuumh y d r a u l icOF 2)pump is not used, fillr e s e r v o i r w i t h o il(page 11-79).T i g h t e n h y d r a u l i c r e s e r v o i r f i llcap (1).Start engine and operate at idlespeed for two minutes then in-crease engine speed to fullthrottle for two minutes.Pull out fuel SHUT OFF control tostop engine but keep ignition keyswitch in RUN position.Check that auxiliary steeringpump and motor is operating; ifi t i s n o t o p e r a t i n g , g o t o t r o u-bleshooting (page 3-137) .Before performing following step, warn personnel to stay away from sideso f l o a d e r b e t w e e n f r o n t a n d r e a r c h a s s i s . F a i l u r e t o d o s o w i l l c a u sedeath or serious injury to those personnel due to chassis pivoting andc r u s h i n g t h e m .I f p e r s o n n e l a r e i n j u r e d , o b t a i n m e d i c a l a s s i s t a n c eimmediately.(o) Wait one minute then turn steering wheel all the way to the right thenall the way to the left to bleed air from system.(p) Set ignition key switch to OFF position.( q ) C h e c k f o r o i l l e a k a g e a t a u x i l i a r y s t e e r i n g p u m p a n d m o t o r . T i g h t enf i t t i n g s a s n e c e s s a r y.8-33