TM 5-3805-262-20
DISASSEMBLY
b .
c .
d .
e .
f .
Remove nut (1),
l o c k w a s h e r ( 2 ) , a nd
washer (3).
Remove and discard gasket (4).
Remove three screws (5).
Remove cover (6), gasket (7), and
diaphragm (8). Discard gasket (7) .
Repeat steps c and d above to remove
remaining gasket and diaphragm.
If necessary, loosen and remove long
and short horns (9 and 10) from body
( 1 1 ).
CLEANING
a .
b .
Clean all nonmetallic parts using clean cloth moistened with detergent; dry
u s i n g c l e a n c l o t h.
Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.
W e a r p r o t e c t i v e g o g g l e s a n d g l o v e s a n d u s e o n l y i n a w e l l v e n t i l a t ed
a r e a . A v o i d c o n t a c t w i t h s k i n , e y e s a n d c l o t h e s a n d d o n ' t b r e a t he
vapors .
Do not use near open flame or excessive heat and dont smoke
w h e n u s i n g i t . F a i l u r e t o d o s o c o u l d c a u s e s e r i o u s i n j u r y . I f y ou
b e c o m e d i z z y w h i l e u s i n g c l e a n i n g s o l v e n t , g e t f r e s h a i r a n d m e d i c al
a t t e n t i o n i m m e d i a t e l y . I f c o n t a c t w i t h s k i n o r c l o t h e s i s m a d e , f l u sh
w i t h l a r g e a m o u n t s o f w a t e r.
If contact with eyes is made, wash eyes
with water and get medical aid immediately.
Clean all metallic parts using cleaning solvent P-D-680. Dry using clean
c l o t h .
10-9