TM 5-3805-262-34
REPAIR (SHEET 2 OF 2)
LEGEND
1. Fill cap
2. O-ring
3. Capscrews (6)
4. Cover
5. Gasket
6. Sight gage
7. Drain plug
8. Hydraulic reservoir
i. Apply rust inhibitor to interior of hydraulic reservoir according to accepted
practice.
j.
If necessary, remove drain plug and drain excess rust inhibitor.
k. Remove all parts from hydraulic reservoir ports.
l. Plug hydraulic reservoir ports and openings using paper to prevent entry of
foreign matter.
m. Spray paint exterior of hydraulic reservoir according to accepted practice.
n. After paint has dried, remove all foreign matter used to plug openings.
o. Install drain plug (7) , sight gage (6), gasket (5), cover (4), six capscrews
(3), O-ring (2), and fill cap (1). Close all open ports using masking tape to
prevent entry of foreign matter.
p. Install hydraulic reservoir if necessary (page 3-753).
4-281 (4-282 blank)