TM 5-3805-262-34PRESSURE TESTa.b.c.d.e.f.g.Position gasket (5) and cover (4)and secure using six capscrews (3).Tighten capscrews securely.Install O-ring (2) and fill cap (1);tighten cap securely.Install parts shown on hydraulicreservoir ports.Using two blocks of wood and twoC-clamps on each hose, close offend of each hose attached to bot-tom and top ports of hydraulicreservoir.WARNINGDon’t apply more than 15 psiair pressure to hydraulicreservoir.To do SO couldcause reservoir to explodecausing death or seriousinjury to personnel.Connect a source of compressedair to 1/4 NPT air hose fittinginstalled in top port of hy-draulic reservoir.Immerse hydraulic reservoir in water tank. Apply 15 psi air pressure to hy-draulic reservoir. Watch water tank for air bubbles indicating leakage of res-ervoir. Using suitable marker, mark locations onbubbles are seen.Relieve air pressure. Remove hydraulic reservoirnect compressed air source.hydraulic reservoir-where airfrom water tank and discon-4-279