TM 5-3805-262-343-4. ALTERNATOR REPAIR (CONT) REASSEMBLY (SHEET 4 OF 5)n.o.p.q.r.s.t.u.v.Push cap (37) onto connector(36).Install connector (36),bracket (35), lock washer(34), and capscrew (33) onslip ring end frame.Push insulator (32) ontovoltage regulator (29)terminals.Connect electrical lead(31) to voltage regulator(29) terminal stud andinstall nut (30).Push voltage regulator (29)terminals into connector(36).Install two springs (28) in brush holder (26) and push two brushes (27) ontosprings (28). Push brushes into brush holder, then insert a toothpickthrough holes in brush holder and brushes to hold brushes in position.Aline three holes in brushholder (26) with three holes involtage regulator (29). Guideend of toothpick in brush holderthrough hole in slip ring endframe, and position brush holderon voltage regulator.Install and tighten capscrews(24 and 25).Install rectifier bridge (23) and two capscrews (22).3-220