Table 2. Machine Control System - Continued.
Table 2. Machine Control System - Continued.

Manual 1 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  548    549    550    551    552  553  554    555    556    557    558  
img
. . . . .
TM 5-3805-290-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 2. Machine Control System - Continued.
(MID 081)
TEST OR INSPECTION
CORRECTIVE ACTION
CID FMI CODE
2. Check harness for an open circuit.
1. If resistance is less than 5.0 Ohms, go
0444 05 -
(a) Turn engine start switch and battery
to Test 3.
Cont.
disconnect switch to OFF position (TM 2. If resistance is greater than 5,000
5-3805-290-10).
Ohms, there is an open circuit in wire
(b) Disconnect wiring harness
751 GN or in wire 921 WH of wiring
connector(s) from machine ECM (WP
harness. Replace wiring harness in
0052 00).
question (WP 0169 00 thru WP 0175
(c) Jumper wire installed in Test 1 remains
00).
in place.
(d) At wiring harness connector, measure
resistance from signal contact J2-7
(wire 374 PK) to contact J2-8 (wire
H803 BU).
3. Verify diagnostic code remains active.
1. If CID 0444 FMI 05 is active, replace
(a) Inspect and clean harness connector
machine ECM (WP 0052 00).
contacts.
2. If CID 0444 FMI 05 is not active, initial
(b) Reconnect all harness connectors.
diagnostic code was probably caused
(c) Turn battery disconnect switch and
by a poor electrical connection at a
engine start switch to ON position (TM
harness connector that was
5-3805-290-10).
disconnected and reconnected.
(d) Operate machine (TM 5-3805-290-
Resume normal machine operation.
10).
(e) Connect MSD (WP 0006 00) and check
status of CID 0444 FMI 05.
0009 00-56