TM 5-3805-290-23-2
ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS - CONTINUED
0022 00
INSTALLATION OF BREAKOUT T AND BYPASS HARNESS - CONTINUED
70-Pin Bypass Harness - Continued
3.
Connect J1/P1 bypass harness adapter to J1/P1 bypass harness as shown.
427-B2153
4.
Separate inline fuse holder.
5.
Remove inline fuse from J1/P1 bypass harness.
6.
Connect J1/P1 bypass harness cable clamps to left bat-
tery as shown.
7.
Connect inline fuse holder.
427-B2154
END OF WORK PACKAGE
0022 00-22