TM 5-3805-290-23-2
THERMOSTAT AND WATER OUTLET MANIFOLD REPLACEMENT - CONTINUED
0043 00
N OT E
Note position of thermostat to ensure correct installation.
Use a container to catch any fluid that may drain from hoses or system. Dispose of fluid IAW local policy and
ordinances. Ensure all spills are cleaned up.
00043 00
THERMOSTAT REMOVAL
1.
Drain coolant from cooling system until coolant level is below thermostat (WP 0042 00).
2.
Loosen hose clamp (1) and disconnect hose (2) from housing (4).
3.
Remove four bolts (3) from housing (4).
4.
Remove housing (4) and gasket (5) from machine. Discard gasket.
427-B0084
5.
Remove ring (6) from housing (4) by bending tabs.
Discard ring.
6.
Remove thermostat (7) from housing (4).
7.
Remove and discard O-ring (8) from thermostat (7).
8.
Remove plug (9) from housing (4).
9.
Remove all gasket material from mating surface of
housing (4).
427-B0085
0043 00-2