THERMOSTAT CLEANING AND INSPECTION
WATER OUTLET MANIFOLD INSTALLATION

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  134    135    136    137    138  139  140    141    142    143    144  
img
.
TM 5-3805-290-23-2
THERMOSTAT AND WATER OUTLET MANIFOLD REPLACEMENT - CONTINUED
0043 00
WATER OUTLET MANIFOLD REMOVAL
00043 00
N OT E
It is not necessary to remove cover
and thermostat in order to remove
water outlet manifold.
Use a container to catch any fluid that
may drain from hoses or system. Dis-
pose of fluid IAW local policy and
ordinances. Ensure all spills are
cleaned up.
1.
Drain coolant from cooling system into container for
storage or disposal (WP 0042 00).
2.
Loosen two hose clamps (10) and disconnect hoses
(11) from water outlet manifold (12).
427-B1064
3.
Loosen two hose clamps (13).
4.
Remove five bolts (14) from water outlet manifold (12).
5.
Remove water outlet manifold (12) and gasket (15)
from machine. Discard gasket.
N OT E
Only perform steps 6 thru 8 if transfer-
ring components.
6.
Remove fitting (16) and plug (17). Set aside for re-
use.
7.
Remove hose (18) from engine.
8.
Remove thermostat and housing from water outlet
427-B0086
manifold. Refer to Thermostat Removal in this work
package.
0043 00-4