MACHINE ELECTRONIC CONTROL MODULE (ECM) REPLACEMENT
COPY CONFIGURATION FROM ECM

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  170    171    172    173    174  175  176    177    178    179    180  
img
TM 5-3805-290-23-2
MACHINE ELECTRONIC CONTROL MODULE (ECM) REPLACEMENT - CONTINUED
0052 00
SYSTEM CONFIGURATION PARAMETERS
0052 00
System configuration parameters affect emissions, engine power, and machine applications. Default values for the
parameters are programmed at the factory. Some parameters (such as Maximum Forward Gear and Maximum Reverse Gear)
may be changed to suit the needs of the specific application.
View and/or change parameters using the Configuration Tool on the toolbar, or by selecting "Configuration" from the
"Service" menu in ET. The Configuration display area in ET has four columns: Description, Value, Unit, and TT. The Descrip-
tion column gives the name of the parameter. The Unit column displays the configuration parameter units. The TT column dis-
plays the list of the total tattletales, which represent the number of times the configuration parameter value has changed.
The push-buttons in the Configuration screen are "Change" or "Print". The "Change" push-buttons allow you to change
the configuration values. This is only enabled if the parameter's configuration can be changed. Parameters that cannot be
changed have a yellow key symbol on the left. The ECM Replacement function in ET copies the relevant configuration param-
eters from one ECM to the other. Table 1 lists the system configuration parameters, data range, default value, and unit for the
924G Wheel Loader.
Table 1. System Configuration Parameters.
PARAMETER
DEFINITION/
RANGE OF
DEFAULT
INPUT
DESCRIPTION
LOCATION
VALUES
VALUE
Product ID
Registration #
8 characters
Blank
Customer defined
Equipment ID
Serial #
17 characters
Blank
Customer defined
Transmission SN
Engine Data Plate
8 characters
Blank
Customer defined
APR07
FLASH
ECM Software Release
5 characters
Date
MONTH YR
(NOV99)
To replace the ECM, perform the following steps, which are explained in more detail in the sections identified below:
a.
Record all diagnostic codes before replacing ECM (WP 0005 00).
b.
Copy configuration of the existing ECM to the MSD. Refer to Copy Configuration from ECM in this work pack-
age.
c.
Remove the ECM. Refer to Remove ECM in this work package.
d.
Install the new ECM. Refer to Install ECM in this work package.
e.
Flash program ECM. Refer to Flash Programming in this work package.
f.
Copy the configuration of the old ECM to the new ECM. Refer to Copy Configuration (Program ECM) in this
work package.