TM 5-3805-290-23-2
TRANSMISSION OIL COOLER BYPASS VALVE MAINTENANCE - CONTINUED
0088 00
REMOVAL - CONTINUED
6.
Disconnect tube assembly (12) from fitting (13). Remove and discard O-ring (14).
7.
Remove fitting (13) from bypass valve (6). Remove
and discard O-ring (15).
8.
Disconnect tube assembly (16) from fitting (17).
Remove and discard O-ring (18).
9.
Remove fitting (17) from bypass valve (6). Remove
and discard O-ring (19).
10.
Remove two mounting bolts (20) and washers (21)
from bracket (22) and remove bypass valve (6) from
machine.
11.
Remove three bolts (23), washers (24), and bypass
valve (6) from bracket (22).
DISASSEMBLY
1.
Remove fitting (25), adapter (26), and O-ring (27)
from bypass valve (6). Discard O-ring.
2.
Remove valve assembly (28) and O-ring (29) from
bypass valve (6). Discard O-ring.
427-B0372
CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to do so may
result in injury or death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Make sure
air stream is directed away from user and other personnel in the area. To prevent injury, user must
wear protective goggles or face shield. Failure to follow this warning may result in injury to personnel.
1.
Clean all parts and mating surfaces with solvent cleaning compound.
2.
Dry parts with compressed air.
3.
Inspect all parts for wear, pitting, cracks, or corrosion and replace if necessary.
4.
Inspect oil passages to ensure they are clean and unobstructed.
0088 00-3