TM 5-3805-290-23-2
GEAR MOTOR HYDRAULIC FAN REPLACEMENT - CONTINUED
0187 00
C AU T I O N
Wipe area clean around all connections to be opened during removal. Cap lines and hoses and plug
openings after removing lines. Contamination of system could result in premature failure.
N OT E
Tag hoses prior to removal to ensure correct installation.
Use a container to catch any fluid that may drain from hoses or system. Dispose of fluid IAW local policy
and ordinances. Ensure all spills are cleaned up.
REMOVAL
1.
Remove 20 fan guard bolts (1) and washers (2) from
fan guard (3).
2.
Remove fan guard (3) from machine.
427-B0760
3.
Disconnect three hose assemblies (4) from fan motor
(5).
4.
Remove and discard three O-rings (6) from hose
assemblies (4).
427-B0761
0187 00-2