SECONDARY FUEL FILTER AND BASE REPLACEMENT - CONTINUED
ETHER STARTING AID REPLACEMENT

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1242    1243    1244    1245    1246  1247  1248    1249    1250    1251    1252  
img
TM 5-3805-291-23-1
SECONDARY FUEL FILTER AND BASE REPLACEMENT - CONTINUED
0036 00
INSTALLATION - CONTINUED
11.
Prime fuel system (TM 5-3805-291-10).
12.
Run engine until normal operating temperature is reached (TM 5-3805-291-10).
13.
Shut down engine (TM 5-3805-291-10).
14.
Check for leaks.
15.
Install right side cover on machine (WP 0135 00).
16.
Close hood (TM 5-3805-291-10).
END OF WORK PACKAGE