ETHER STARTING AID REPLACEMENT - CONTINUED
0037 00
INSTALLATION - CONTINUED
N OT E
Hole in atomizer must be aligned parallel with center line of air flow and must be oriented against the
direction of the air flow. Use mark on hex head.
3.
Position atomizer assembly (11) and install two washers (21) and bolts (20) on machine.
4.
Connect chassis wiring harness (19) to atomizer assembly (11).
5.
Install new O-ring (18) and fitting (17) on machine.
6.
Install new sleeve (16) and nut (15) on fitting (17).
7.
Position line (5) on machine.
8.
Connect line (5) to nut (15).
9.
Install union (14) on line (5).
10.
Install line (13) on union (14).
11.
Install union (12) on line (13).
12.
Position line (4) on machine.
13.
Connect line (4) to union (12).
14.
Install new O-ring (10) and connector (9) on atomizer assembly (11).
427-C0332-1