MUFFLER AND EXHAUST PIPE REPLACEMENT - CONTINUED
MUFFLER AND EXHAUST PIPE REPLACEMENT - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1257    1258    1259    1260    1261  1262  1263    1264    1265    1266    1267  
img
TM 5-3805-291-23-1
MUFFLER AND EXHAUST PIPE REPLACEMENT - CONTINUED
0040 00
REMOVAL - CONTINUED
2.
Loosen clamp (2) and disconnect tube assembly (3)
from muffler (1).
3.
Remove two bolts (4), spacers (6), nuts (7), and four
washers (5) from muffler (1).
4.
Repeat step 3 for other side.
5.
With assistance, remove muffler (1) from machine.
427-C0201
CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to do so may
result in injury or death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Make
sure air stream is directed away from user and other personnel in the area. To prevent injury, user
must wear protective goggles or face shield. Failure to follow this warning may result in injury to per-
sonnel.
1.
Clean all parts and surfaces with solvent cleaning compound.
2.
Dry parts with compressed air.
3.
Inspect all parts for damage, wear, pitting, cracks, or corrosion and replace if necessary.
0040 00-3