TM 5-3805-291-23-2
IMPLEMENT ELECTRONIC CONTROL MODULE (ECM) REPLACEMENT - CONTINUED
0060 00
REMOVE ECM - CONTINUED
4.
Disconnect upper cab wiring harness (4) from lower
cab wiring harness (5).
5.
Disconnect wiring harness (6) from ECM (7).
6.
Remove four bolts (8), washers (9), spacers (10), rear
washers (11), and ground strap (12) from ECM (7).
7.
Remove ECM (7) from machine.
8.
Remove eight mounts (13) from ECM (7).
INSTALL ECM
1.
Install eight mounts (13) on ECM (7).
2.
Position ECM (7) on machine.
3.
Install ground strap (12), four rear washers (11), spac-
ers (10), washers (9), and bolts (8) on ECM (7).
4.
Connect wiring harness (6) to ECM (7).
5.
Tighten socket-head screw for connectors to 53 lb-in.
(6 Nm).
6.
Connect upper cab wiring harness (4) to lower cab
wiring harness (5).
7.
Install interior panel (3), two screws (2), and three
screws (1) on machine.
8.
Proceed to Flash Programming in this work package.
9.
00060 00
FLASH PROGRAMMING
1.
Turn battery disconnect switch to ON position (TM 5-3805-291-10).
2.
Connect ET to MSD and start ET (WP 0005 00).
3.
Highlight the ECM and click "OK".
4.
Insert flash file CD and read the "read me" file. Note the correct ECM flash file and folder name.
5.
Select "WinFlash" from the "Utilities" menu in ET. "WinFlash" will attempt to detect an ECM. Read and close the Win-
Flash Quick Help Guide.
0060 00-5