TM 5-3805-291-23-2
BATTERIES REPLACEMENT - CONTINUED
0096 00
REMOVAL
WAR N I N G
Be careful not to touch tool used to disconnect cable clamp to any part of machine. Sparks may occur
resulting in injury to personnel or damage to equipment.
N OT E
Steps 1 thru 10 remove two batteries from upper battery compartment. Steps 11 thru 19 remove two
batteries from lower battery compartment for machines equipped with arctic heater.
Disconnect negative (black) cable first.
1.
Pull back cover (1) on cable clamp (19).
2.
Loosen nut (18) and disconnect cable clamp (19) on cable (2) from battery (17).
3.
Pull back two covers (3 and 9) from cable clamps (16).
4.
Loosen two nuts (15) and disconnect two cable clamps (16) from batteries (14 and 17).
5.
Remove battery cable (7) from machine.
6.
Pull back cover (11) on cable clamp (13).
7.
Loosen nut (12) and disconnect cable clamp (13) on cable (10) from battery (14).
0096 00-2