TM 5-3805-291-23-2
MAIN CONTROL VALVE AND IMPLEMENT PUMP HYDRAULIC
HOSES, LINES, AND FITTINGS REPLACEMENT - CONTINUED
0157 00
INSTALLATION - CONTINUED
24.
Install three new O-rings (24) in hoses (16, 22, and 23)
and connect hoses to main hydraulic control valve (2).
427-C1296
25.
26.
Install new O-ring (21) in fitting (19) and install fitting on machine.
27.
Install two O-rings (20) in tube (18) and connect tube to main hydraulic control valve (2) and fitting (19).
28.
Install new O-ring (17) in hose (16) and connect hose to main hydraulic control valve (2).
29.
Install two new gaskets (14) on two tilt cylinder hoses (15) on main hydraulic control valve (2). Install eight washers
(13) and bolts (12).
30.
Install four new gaskets (9) on four lift cylinder hoses (10 and 11) on main hydraulic control valve (2). Install 16 wash-
ers (8) and bolts (7).
31.
Install two new gaskets (5) on two third function hoses (6) on main hydraulic control valve (2). Install eight washers (4)
and
bolts (3).
32.
Connect wiring harness (1) to main hydraulic control valve (2).