TM 5-3805-292-10
0020
Table 1. Preventive Maintenance Checks and Services (PMCS)
for the M400T and M400W SSL - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT READY/
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
AVAILABLE IF:
52
After
Lights
Inspect rear lights for breaks or
Lights damaged.
other damage. If dirty, clean lights
with a rag and windshield cleaning
compound.
53
After
ROPS/FOPS Inspect two ROPS/FOPS mounting Either bolt is missing,
Mounting Bolts bolts outside cab. Ensure neither is loose, or damaged.
missing, loose, or damaged.
54
After
Engine
a. Lift up on handle and open
Door or strut inoperable.
Compartment
upper access door. Check door
strut.
ROPS/FOPS
MOUNTING BOLTS
UPPER ACCESS
DOOR HANDLE
458-0016
Figure 38. ROPS/FOPS Mounting Bolts and Upper Access Door.
0020
not secure.
hoses are securely mounted to
upper access door.
c. Reach behind top left of lower
access door and lift up on
release lever to open lower
access door.