Table 1. Preventive Maintenance Checks and Services (PMCS) for the M400T and M400W SSL - Continued.
Table 1. Preventive Maintenance Checks and Services (PMCS) for the M400T and M400W SSL - Continued.

Operators Manual For M400T And M400W
Page Navigation
  180    181    182    183    184  185  186    187    188    189    190  
img
.
TM 5-3805-292-10
0020
Table 1. Preventive Maintenance Checks and Services (PMCS)
for the M400T and M400W SSL - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT READY/
NO.
INTERVAL
HOURS
PROCEDURE
AVAILABLE IF:
SERVICE
55
After
Backup Alarm a. At top inside of lower access
Damage or looseness to
backup alarm.
and Backup
door, inspect backup alarm for
Alarm/Lights
looseness or damage.
Wiring
Harnesses
b. Inspect wiring harness leads to
Damage that would impair
operation is evident.
backup alarm and lights for
looseness or damage. If
disconnected, connect
connectors to backup alarm/
lights.
LIGHTS
BACKUP
ALARM
WIRING
HARNESS
458-0018
Figure 39. Backup Alarm, Lights, and Wiring Harness.
0020
0020-45