TM 5-3805-292-10
0020
Table 1. Preventive Maintenance Checks and Services (PMCS)
for the M400T and M400W SSL - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT READY/
NO.
INTERVAL
HOURS
PROCEDURE
AVAILABLE IF:
SERVICE
70
Initial 100
M400W: Chain
Hours
Tank Oil
NOTE
If machine is new, chain tank oil should be serviced after initial 100 hours of operation.
Notify Field Maintenance to change
chain tank and replace oil filter.
71
250 Hours
Cab Air Filter
WARNING
If NBC exposure is suspected, personnel wearing protective equipment must handle all air cleaner media.
Contaminated filters must be handled using adequate precautions and must be disposed of by trained
personnel. Consult your NBC Officer or NBC NCO for appropriate handling or disposal procedures. Failure
to follow this warning may cause injury or death to personnel.
NOTE
Service cab air filter as conditions warrant if operating in extreme environmental conditions.
a. At top rear of cab, loosen two
thumbscrews and remove cover
from filter compartment.
Figure 51. Cab Air Filter Compartment.