TM 5-3805-292-10
0020
Table 1. Preventive Maintenance Checks and Services (PMCS)
for the M400T and M400W SSL - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT READY/
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
AVAILABLE IF:
72
500 Hours
Engine Air
Service engine air cleaner
or if light is
Cleaner
on
73
500 Hours
Fuel Filter
WARNING
DO NOT perform fuel system checks, inspections, or maintenance while smoking or near fire, flames, or
sparks. Fuel may ignite, causing damage to equipment and injury or death to personnel.
Wear fuel-resistant gloves and eye protection when handling fuels. If exposed to fuel, promptly wash
exposed skin and change fuel-soaked clothing.
Failure to follow these warnings may result in injury or death to personnel.
NOTE
A suitable container should be placed under fuel filter to capture draining fuel. Dispose of fuel IAW using
unit's SOP. Ensure all spills are cleaned up IAW spill containment plan.
a. Loosen two thumbscrews and
remove access cover to right