TENSION ADJUSTMENT
Figure 2. Battery Compartment Cover Plate.

Operators Manual For M400T And M400W
Page Navigation
  213    214    215    216    217  218  219    220    221    222    223  
img
. . . . . . . . . . . . . .
4
TM 5-3805-292-10
0024
OPERATOR MAINTENANCE
-
RETURNING MACHINE TO SERVICE AFTER PERIODS OF NON-USE
0024
REMOVAL FROM STORAGE AFTER 30 TO 90 DAYS, REMOVAL FROM STORAGE AFTER 90 DAYS
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
0
0
Wrench, Tamper Resistant (WP 0031, Table 2,
Machine parked on level ground (WP 0005)
0
Item 7)
Loader arms lowered to ground (WP 0005)
0
0
Engine off (WP 0005)
Materials/Parts
0
0
Parking brake engaged (WP 0005)
0
Cleaning Compound, Windshield (WP 0033,
Item 3)
Estimated Time To Complete
0
0
Rag, Wiping (WP 0033, Item 12)
2.0 Hrs
0
0
References
0
WP 0020
0
REMOVAL FROM STORAGE AFTER 30 TO 90 DAYS
0024
1. Perform all Before operations in PMCS for machine and work tool attachments (WP 0020).
2. Perform "10 Hour" and "50 Hour" procedures in PMCS (WP 0020).
3. Drain fuel filter per "500 Hour" PMCS procedure (WP 0020).
NOTE
In time, stored fuel will darken due to oxidation. The darkening is accompanied by the
formation of sediment that plugs filters and causes poor combustion.
4. Inspect fuel for evidence of hazing or darkening. If either condition is present, notify Field Maintenance.
5. Ensure fire extinguisher (Figure 1, Item 1) is securely mounted in bracket behind seat and is not damaged.
6. Ensure fire extinguisher is still charged (WP 0020).
Figure 1. Fire Extinguisher.
0024
0024-1