ENGINE TROUBLESHOOTING - ENGINE DOES NOT CRANK CONTINUED
ENGINE TROUBLESHOOTING - ENGINE DOES NOT CRANK CONTINUED

Field Maintenance Manual For M400T And M400W
Page Navigation
  27    28    29    30    31  32  33    34    35    36    37  
img
. . . . . . . . . . . . . .
TM 5-3805-292-23
0006
ENGINE TROUBLESHOOTING - ENGINE DOES NOT CRANK CONTINUED
B
WARNING
To avoid injury, eye protection and acid-resistant gloves must be worn when working around batteries.
DO NOT smoke, use open flame, make sparks, or create other ignition sources around batteries. If a
battery is giving off gases, it can explode and cause injury to personnel. Remove all jewelry such as
rings, ID tags, watches, and bracelets. If jewelry or a tool contacts a battery terminal, a direct short will
result in instant heating or electric shock, damage to equipment, and injury to personnel.
Reinstall starting relay (TM 5-3805-292-10).
Temporarily swap starting relay with
Remove start interlock relay from fuse box
start interlock relay in fuse box (TM 5-
(TM 5-3805-292-10).
3805-292-10).
Turn machine power ON.
Momentarily connect a jumper wire to
Engine
Connect a jumper wire to start interlock
start interlock relay pins 30, circuit
NO
relay pins 30, circuit 622D (W), fuse box
cranked?
622D (W), fuse box side, and 87 circuit
side, and 87 circuit 622A (O), fuse box side
622A (O), fuse box side to see if
(WP 0175, Frame 10. Power Center).
engine cranks (WP 0175, Frame 10.
Attempt to crank engine (TM 5-3805-292-
Power Center).
10).
YES
Reinstall start interlock relay (TM 5-3805-
292-10).
Engine
Turn machine power OFF.
F
NO
cranked?
Disconnect auxiliary hydraulic spool neutral
switch C126 from main hydraulic valve (WP
0089). Disconnect instrument panel (IP)
CONTINUED
C23 (WP 0155). Check for continuity
(page 0006-8)
between C23-5, circuit 602C (W), harness
YES
side and C126-A, circuit 602D (W), harness
side (WP 0175, Frame 12. RH Console,
and Frame 20. Aux Override System).
Replace starting relay (TM 5-3805-
292-10).
Continuity
Perform open harness test for circuit
NO
present?
602 (WP 0173).
YES
C
CONTINUED
(page 0006-5)