TM 5-3805-292-23
0006
ENGINE TROUBLESHOOTING - ENGINE DOES NOT CRANK CONTINUED
F
IP power
Perform open harness test for circuit
Check if IP power is on (TM 5-3805-292-10).
NO
on?
YES
Turn machine power on and attempt to
crank (TM 5-3805-292-10). Remove IP but
12V
Replace instrument panel
NO
voltage between IP C23-9, circuit 622E
present?
(W), harness side and ground
YES
Remove start interlock relay
(TM 5-3805-292-10).
Press and hold start button (TM 5-3805-
12V
Perform open harness test for
292-10).
NO
Measure voltage between start interlock
present?
relay pin 30, circuit 622D (W), fuse box
Power Center). Release start button.
YES
Replace start interlock relay
Perform relay test on start interlock relay
Relay okay?
NO
(TM 5-3805-292-10).
YES
Turn machine power OFF.
Remove starting relay (TM 5-3805-292-10).
Repair circuit 622 or replace
relay pin 87, circuit 622A (O), fuse box side,
NO
present?
and starting relay pin 86, circuit 622J (O),
Center).
YES
Replace starting relay
Perform relay test on starting relay
Relay okay?
NO
(TM 5-3805-292-10).
YES
Repair circuit 178 or replace chassis