Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.

Field Maintenance Manual For M400T And M400W
Page Navigation
  147    148    149    150    151  152  153    154    155    156    157  
img
. . .
TM 5-3805-292-23
0009
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
10
500 Hours
1.0
e. Check battery cables for
Battery cables damaged
(Cont)
corrosion.
or corroded.
f. Install batteries (WP 0130).
g. Check battery hold-downs for
Hold-down is damaged,
looseness, corrosion, or damage. If loose, or missing.
loose, tighten.
h. Clean battery terminals with an
abrasive cloth.
i. Close battery box cover (TM 5-
3805-292-10).
Engine
Breather
11
500 Hours
0.5
Clean breather and replace gasket
(WP 0028).
WARN I N G
Hydraulic Oil
Filter
Element
Contact with engine/hydraulic oil can damage skin.
Wear gloves when handling engine/hydraulic oil. If oil
contacts skin, wash it off immediately. Failure to follow
this warning may result in injury to personnel.
12
500 Hours
0.5
Replace hydraulic oil filter element
(WP 0072).