• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 5. Final Drive Motor.
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.

Field Maintenance Manual For M400T And M400W
Page Navigation
  150    151    152    153    154  155  156    157    158    159    160  
img
. .
TM 5-3805-292-23
0009
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
15
b. If auger point is worn or
b. Auger point is worn.
(Cont)
damaged and cannot be reused,
replace auger point.
16
600 Hours
0.5
Check nitrogen charge level of
Charge is low.
hammer (WP 0153).
WARN I N G
Inline Fuel
Filter
DO NOT perform fuel system checks, inspections, or
maintenance while smoking or near fire, flames, or
sparks. Fuel may ignite.
 Wear fuel-resistant gloves and eye protection when
handling fuels. If exposed to fuel, promptly wash
exposed skin and change fuel-soaked clothing.
 Failure to follow these warnngs may result in injury to
i
personnel.
17
1,000 Hours
0.5
Replace inline fuel filter (WP 0016).
WARN I N G
Hydraulic
Fluid
Contact with engine/hydraulic oil can damage skin.
Wear gloves when handling engine/hydraulic oil. If oil
contacts skin, wash it off immediately. Failure to follow
this warning may result in injury to personnel.
a. Lower loader arms (TM 5-3805-
292-10).
b. Remove drain plug from
hydraulic tank and drain hydraulic
fluid (LO 5-3805-292-13).
0009-14