INTAKE MANIFOLD REPLACEMENT
INTAKE MANIFOLD REPLACEMENT - Continued

Field Maintenance Manual For M400T And M400W
Page Navigation
  359    360    361    362    363  364  365    366    367    368    369  
img
.
TM 5-3805-292-23
0045
REMOVAL
00045
Disconnect line (Figure 1, Item 3) and remove bolt (Figure 1, Item 5), seven bolts (Figure 1, Item 4), manifold (Fig-
ure 1, Item 1), and gasket (Figure 1, Item 6) from engine (Figure 1, Item 2). Discard gasket.
WAITING ON ART # 458-0933
Figure 1. Manifold.
0045
END OF TASK
CLEANING AND INSPECTION
00045
1. Remove all gasket material from mating surfaces.
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
2. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.