Figure 4. Cylinder Head.
Figure 5. Cylinder Head.

Field Maintenance Manual For M400T And M400W
Page Navigation
  390    391    392    393    394  395  396    397    398    399    400  
img
.
TM 5-3805-292-23
0053
CLEANING AND INSPECTION
00053
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
1. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
2. Dry parts with compressed air.
3. Inspect parts for wear, pitting, cracks, or corrosion and replace if necessary.
END OF TASK
INSTALLATION
00053
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure that lifting device is in good condition and of suitable
load capacity. Keep clear of heavy parts supported only by lifting device.
Failure to follow these warnings ma result in injury to personnel.
y
N OT E
Install head bolts as noted during removal.
1. Install new gasket (Figure 5, Item 5) on engine (Figure 5, Item 6).
2. Install fan support (WP 0054).
3. Attach lifting device to cylinder head assembly (Figure 5, Item 4).