Figure 11. Deluxe Heater A/C Assembly Installation.
Figure 15. End Cap Covers and Retaining Hardware.

Field Maintenance Manual For M400T And M400W
Page Navigation
  891    892    893    894    895  896  897    898    899    900    901  
img
.
TM 5-3805-292-23
0130
INSTALLATION CONTINUED
N OT E
Remove all caps from ports and hoses before installing hoses.
4. Install two new O-rings (Figure 13, Item 2) on A/C hose fittings (Figure 13, Item 1).
2
1
458-1139
Figure 13. O-rings on A/C Hose Fittings.
0130
N OT E
Install hoses as noted during removal.
5. Connect two A/C hoses (Figure 14, Item 1) on evaporator (Figure 14, Item 2).
Figure 14. A/C Hose Connections on Evaporator.
0130
0130-15