BACKUP ALARM REPLACEMENT
BACKUP ALARM PRESSURE SWITCH REPLACEMENT

Field Maintenance Manual For M400T And M400W
Page Navigation
  933    934    935    936    937  938  939    940    941    942    943  
img
. .
TM 5-3805-292-23
0139
REMOVAL
000139
N OT E
Tag wires and electrical connectors to aid in installation.
1. Loosen two nuts (Figure 1, Item 1) and remove wires (Figure 1, Item 2) from backup alarm (Figure 1, Item 3).
2. Loosen two bolts (Figure 1, Item 4), washers (Figure 1, Item 5), and nuts (Figure 1, Item 6), and remove
backup alarm (Figure 1, Item 3) from machine.
Figure 1. Backup Alarm.
0139
END OF TASK
INSTALLATION
000139
1. Install backup alarm (Figure 1, Item 3) on machine and tighten two washers (Figure 1, Item 5), bolts (Figure 1,
Item 4), and nuts (Figure 1, Item 6).
N OT E
Install wires and electrical connectors as tagged during removal.
2. Install two wires (Figure 1, Item 2) on backup alarm (Figure 1, Item 3) and tighten two nuts (Figure 1, Item 1).
END OF TASK
FOLLOW-ON TASKS
000139
1. Close rear access door (TM 5-3805-292-10).
2. Connect battery power (WP 0142).
3. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE