TM 5-3805-292-23
0140
INSTALLATION
000140
N OT E
Install wires and electrical connectors as tagged during removal.
1. Install new O-ring (Figure 2, Item 4) and switch (Figure 2, Item 3) on machine and connect wiring harness
(Figure 2, Item 2) to switch.
2. Install new O-ring (Figure 1, Item 4) and switch (Figure 2, Item 1) on machine and connect wiring harness
(Figure 2, Item 5) to switch.
Figure 2. Backup Alarm Pressure Switch.
0140
END OF TASK
FOLLOW-ON TASKS
000140
3. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE