BACKUP ALARM PRESSURE SWITCH REPLACEMENT - Continued
BATTERIES REPLACEMENT

Field Maintenance Manual For M400T And M400W
Page Navigation
  936    937    938    939    940  941  942    943    944    945    946  
img
. . .
TM 5-3805-292-23
0140
INSTALLATION
000140
N OT E
Install wires and electrical connectors as tagged during removal.
1. Install new O-ring (Figure 2, Item 4) and switch (Figure 2, Item 3) on machine and connect wiring harness
(Figure 2, Item 2) to switch.
2. Install new O-ring (Figure 1, Item 4) and switch (Figure 2, Item 1) on machine and connect wiring harness
(Figure 2, Item 5) to switch.
Figure 2. Backup Alarm Pressure Switch.
0140
END OF TASK
FOLLOW-ON TASKS
000140
1. Connect battery power (WP 0142).
2. Close ROPS (WP 0134).
3. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE
0140-3/(4 blank)