Figure 1. Grid Heater and Starter Relays.
HYDRAULIC OIL TEMPERATURE SENDER REPLACEMENT

Field Maintenance Manual For M400T And M400W
Page Navigation
  1065    1066    1067    1068    1069  1070  1071    1072    1073    1074    1075  
img
. .
TM 5-3805-292-23
0161
INSTALLATION
000161
N OT E
Connect cables and wires to terminals as noted during removal.
1. Install four bolts (Figure 1, Item 11), grid heater relay (Figure 1, Item 8), starter relay (Figure 1, Item 6), four
washers (Figure 1, Item 9), and nuts (Figure 1, Item 10) to machine.
2. Install four red cables (Figure 1, Item 4), and four nuts (Figure 1, Item 5), to grid heater relay (Figure 1, Item 8)
and starter relay (Figure 1, Item 6).
3. Slide four rubber boots (Figure 1, Item 1) over four red cables (Figure 1, Item 4).
4. Connect push-on terminal (Figure 1, Item 7) to grid heater relay (Figure 1, Item 8).
5. Install three wire terminals (Figure 1, Item 3), and three small nuts (Figure 1, Item 2), to grid heater relay (Fig-
ure 1, Item 8) and starter relay (Figure 1, Item 6).
END OF TASK
FOLLOW-ON TASKS
000161
1. Connect battery power (WP 0142).
2. Close ROPS (WP 0134).
3. Verify correct operation of grid heater and starter relays.
END OF TASK
END OF WORK PACKAGE