GRID HEATER AND STARTER RELAYS REPLACEMENT - Continued
HYDRAULIC OIL TEMPERATURE SENDER REPLACEMENT - Continued

Field Maintenance Manual For M400T And M400W
Page Navigation
  1066    1067    1068    1069    1070  1071  1072    1073    1074    1075    1076  
img
. . . . . . . . . .
4
TM 5-3805-292-23
0162
FIELD MAINTENANCE
-
HYDRAULIC OIL TEMPERATURE SENDER REPLACEMENT
0162
REMOVAL, CLEANING AND INSPECTION, INSTALLATION
INITIAL SETUP
Tools and Special Tools
References
0
0
Tool Kit, General Mechanic's (WP 0178, Item
TM 5-3805-292-10
0
33)
TM 5-3805-292-23P, Figure 26
0
0
Materials/Parts
Equipment Conditions
0
0
Cap Set, Protective (WP 0179, Item 2)
ROPS tilted (WP 0134)
0
0
Cleaning Compound, Solvent, Type III (WP
Battery power disconnected (WP 0142)
0
0179, Item 3)
0
Estimated Time to Complete
Rag, Wiping (WP 0179, Item 19)
0
0
0.4 Hr
Sealing Compound (WP 0179, Item 25)
0
0
Lockwasher
0
REMOVAL
000162
N OT E
Plug opening to prevent excess spillage of hydraulic fluid.
1. Remove nut (Figure 1, Item 4) and lockwasher (Figure 1, Item 3) and disconnect wire (Figure 1, Item 5) from
sender (Figure 1, Item 2). Discard lockwasher.
2. Remove sender (Figure 1, Item 2) from elbow (Figure 1, Item 1).
Figure 1. Hydraulic Oil Temperature Sender.
0162
END OF TASK
0162-1