TM 5-3805-298-23-1
0018
Table 1. E0236 Return Hydraulic Oil Filter Plugged Event Code - Continued.
018
EID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 5. Test Hydraulic Oil Filter
E0236 Return Hydraulic Oil
Bypass Switch Signal Circuit for a
Filter Plugged Event Code -
Short to Ground in Lower Cab Wiring
Continued
Harness.
1. Remove left lower cab access
panels (WP 0347).
2. Remove transmission ECM cover
(WP 0266).
3. Disconnect connector C-C13
transmission ECM J2.
harness (WP 0291).
between connector C-C13
Proceed to Test Step 6.
No Continuity - Replace transmission
and ground.
ECM (WP 0266).
Proceed to Test Step 6.
Test Step 6. Verify Symptom Is
Resolved.
1. Ensure all harness connectors are
connected.
2. Install rear frame wiring harness
connector (Figure 1, Item 1), new
lockwasher (Figure 1, Item 3), and
nut (Figure 1, Item 2) on hydraulic
filter bypass switch (Figure 1,
Item 4).
3. Start and idle engine until normal
operating temperature (hydraulic
oil 110F) is reached (TM 5-3805-
298-10).
Event Code E0236 Is Active - Repeat
event code E0236 is not active.
troubleshooting from the beginning.
Event Code E0236 Not Active -
Troubleshooting complete.
END OF WORK PACKAGE