Table 1. Engine Does Not Crank or Cranks Slowly - Continued.
Table 1. Engine Does Not Crank or Cranks Slowly - Continued.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  470    471    472    473    474  475  476    477    478    479    480  
img
.
TM 5-3805-298-23-1
0036
Table 1. Engine Does Not Crank or Cranks Slowly - Continued.
036
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Using a digital multimeter
Engine Does Not Crank or
Resistance 5.0 Ohms or Less -
(WP 0174), measure resistance
Cranks Slowly - Continued
Replace starter motor (WP 0240).
between engine wiring harness
Install left engine access panel
terminal (Figure 15, Item 5) at
(WP 0350).
starter motor (Figure 15, Item 6)
Proceed to Test Step 10.
and engine wiring harness terminal
Resistance Greater Than 5.0 Ohms -
(Figure 15, Item 1).
Replace engine wiring harness
(WP 0299).
Proceed to Test Step 10.