Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  1228    1229    1230    1231    1232  1233  1234    1235    1236    1237    1238  
img
.
TM 5-3805-298-23-1
0121
Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
0121
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
Condenser Fan(s) Do Not
Operate When the Heater A/
C Switch Is in A/C Position -
Continued
Flying particles may be ejected while fans are in operation. Wear eye
protection and gloves while performing inspection.
Failure to follow this warning may cause injury to personnel.
4. Visually inspect primary condenser
All Three A/C Condenser Fans
fans (Figure 2, Item 1) and
Operate Proceed to Test Step 33.
auxiliary fan (Figure 2, Item 2)
All Three A/C Condenser Fans Do
operation (TM 5-3805-298-10).
Not Operate Proceed to Test Step 5.
Figure 2. Primary and Auxiliary Condenser Fans.