• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
DOME LIGHT DOES NOT OPERATE

Field Maintenance Manual For 924H Wheel Loader -1 Page Navigation
  1243    1244    1245    1246    1247  1248  1249    1250    1251    1252    1253  
img
.
TM 5-3805-298-23-1
0121
Table 1. Condenser Fan(s) Do Not Operate When the Heater A/C Switch Is in A/C Position - Continued.
0121
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Turn heater A/C switch to A/C on
Condenser Fan(s) Do Not
(TM 5-3805-298-10).
Operate When the Heater A/
7. Turn heater control knob to
C Switch Is in A/C Position -
maximum cold (TM 5-3805-298-
Continued
10).
WARNING
Flying particles may be ejected while fans are in operation. Wear eye
protection and gloves while performing inspection.
Failure to follow this warning may cause injury to personnel.
8. Visually inspect primary condenser
All A/C Condenser Fans Operate
fans (Figure 5, Item 1) and
Troubleshooting complete.
auxiliary fan (Figure 5, Item 2)
One or More A/C Condenser Fans Do
operation (TM 5-3805-298-10).
Not Operate Repeat troubleshooting
from the beginning.
Figure 5. Primary and Auxiliary Condenser Fans.
0121
END OF WORK PACKAGE